Features:

1. LCD display

2. Double control modes of bed temperature and skin temperature

3. Double-layer thermostatic cover, automatic air curtain device

4. Humidity control function

5. Air & Oxygen blender

6. Oxygen supply system

7. Baby cot is infinitely adjustable

8. 24 kinds of sound and light alarm, comprehensive protection of baby safety

Technical Parameters:

General Parameters

Item

Specifications

Power Supply

AC220V, 50/60Hz(Standard) 1320VA; 110V 60Hz(Optional)

Size(L*W*H)

950*645*(1250-11450) mm

Maximum Heater Output Power(220VAC)

Air chamber heater: 330W;

Water tank heater: 155W

Auxiliary Network Power Output

AC220V/50Hz, both maximum permissible currents are 220V 1.5A

Heater Indication

0~100%, 10% increasing amount

Temperature Control Mode

Bed temperature mode; The skin temperature mode

Bed Temperature Control Range

25.0~37.0℃; 37.1~39.0℃(Span mode)

Skin Temperature Control Range

34.0~37.0℃; 37.1~38.0℃(Span mode)

Skin Temperature Sensor Display Range

5.0~65.0℃

Heating Time

≤50min

Temperature Variability

≤0.5℃

Temperature Uniformity (Mattress in horizontal position)

≤0.8℃

Temperature Uniformity (Mattress in tilted position)

≤1.0℃

Difference Between Average Incubator Temperature And Control Temperature

≤1.5℃

Skin Temperature Sensor Accuracy

±0.3℃

Humidity Control

The Running Time Of The Tank After It Is Filled With Distilled Water

Humidity below 70%RH, at least 24h

Water Tank Capacity

1500ml

Humidity Display Range

0%RH~99%RH

Humidity Control Range

CAH%RH~90%RH(1% per adjustment)

Humidity Control Accuracy

±10%

Oxygen Concentration Control

Oxygen Concentration Display Range

0%~99%

Oxygen Concentration Display Resolution

1%

Oxygen Concentration Control Accuracy

±5% oxygen volume concentration

Oxygen Concentration Setting Range

21%~60% (1% per adjustment)

Oxygen Sensor Service Life

The maximum use time is 10000h at 100% oxygen concentration

Transport Storage

Temperature

-20℃~+55℃

Atmospheric Pressure Range

500hPa~1060hPa

Relative Humidity

≤93%RH

Packing Size/ Gross Weight

1150*800*1600mm

190kg

The Work Environment

Relative Humidity

30%RH~75%RH

Environment Temperature

+20℃~+30℃

Pressure Range

700hPa~1060hPa

Service Altitude

≤2000m

Overvoltage Category

Pollution Level

2

Ambient Air Velocity

≤ 0.3m/s

Other Indicators

Ambient Noise In The Infant Compartment Of The Incubator

No more than 55dB(A) at stable temperature

Carbon Dioxide Concentration In The Infant Compartment

A mixture of 4% carbon dioxide and air was fed into an 8mm diameter tube in the vertical direction from the mat to the top of the box at 750mL /min to a point 10cm above the mattress center and 10cm above the center. The concentration was less than 0 5% after stabilization

The Velocity Of Air Flow Over The Baby Mattress

≤0.35m/s

General

Alarm

Power failure alarm, fan alarm, sensor alarm, deviation alarm, over temperature alarm, water tank placement error alarm, water shortage alarm

System Alarm

Mcu1 and Mcu2 communication error alarm, Mcu2 and Mcu3 communication error alarm, analog-to-digital conversion chip 2544 failure alarm, analog-to-digital conversion chip 2548 failure alarm, over temperature alarm, temperature heating system failure, humidity heating system failure


Configuration:

Model

BK-3201(I)

BK-3201(II)

Temp. Control

Bed/Skin temperature

Bed/Skin temperature

Display

LCD

LCD

Bed Temp. Control Range

25℃-39℃

25℃-39℃

Skin Temp. Control Range

34℃-38℃

34℃-38℃

Humidity Control Range

CAH%~99%RH

CAH%~99%RH

Oxygen Control Range

21%-99%

/

Cabinet

Yes

Yes

 

View full details