Feature:
♦ Six independent temperature control
♦ Thermal compensation technology of temperature module
♦ No edge effect of temperature and optics have
♦ Maintenance-free long - life continuous spectral excitation source
♦ Synchronous and fast acquisition of low temperature CCD 0.15s in cold state
♦ Relative quantitative high sensitivity 1.5 times effective discrimination
♦ Flexible, open and user-friendly software platform
♦ Open reagent consumable platform
Application:
♦ Basic materials research
♦ Pathogen detection
♦ Public health safety surveillance
♦ Meat products adulterated
♦ Transgenic testing
♦ Food safety inspection
♦ Drug development and rational drug use
♦ Precise tumor treatment
♦ Gene expression
♦ Genetic screening
♦ Genotyping
♦ Stem cell research
Temperature control module
On the basis of the six independent temperature control technology, using the enclosed liquid heat transfer efficiency, combined with environmental scanning monitoring regulation auxiliary infrared with heating and intelligent variable frequency system voltage, current, ensures the module heating speed, effectively prevents temperature overshoot no edge effect and the evaporation temperature, not only saves your precious time to amplify the required temperature uniformity and the repeatability of the results achieved perfection, no matter what kind of test mode, application, it can get good data uniformity and repeatability.
Models:
Technical parameters:
|
Product Name |
Fluorescence Quantitative PCR Detection System |
||||
|
Model |
MA-6000 |
||||
|
Sample Capacity |
96x0.2ml PCR plate, 12x8-strip tubes, 96*0.2ml single tube |
||||
|
Reaction System |
6~125μl |
||||
|
Dynamics Range |
1-1010 copies |
||||
|
Channel |
5 |
||||
|
Emission Light |
Full-wavelength maintenance-free halogen tungsten lamp |
||||
|
Detector |
-20℃ CCD |
||||
|
Detection Path |
F1 |
F2 |
F3 |
F4 |
F5 |
|
Suitable Probe/Dye |
FAM/SYBR Green/Eva Green/LC Green/Fluorescein |
VIC/HEX/TET/Cy3/JOE/Alex a555 |
ROX/Cy3.5/Texas Red |
Cy5/LC Red640 |
Cy5.5/LC Red705 |
|
Excitation Wavelength |
380~780nm |
||||
|
Detection Wavelength |
380~780nm |
||||
|
Fluorescence Detection Repeatability |
CV≤3% |
||||
|
Fluorescence Detection Precision |
CV≤ 5% |
||||
|
Sample Detection Repeatability |
CV≤3% |
||||
|
Fluorescence Detection Linearity |
r≥0.980 |
||||
|
Confidence |
It can effectively distinguish 5000 and 1000copies with99.8% confidence degree |
||||
|
Module Temp. Range |
4-100℃(resolution:0.1℃) |
||||
|
Heating Speed |
5.0℃/s(Max), 3.5℃/ s(Avg) |
||||
|
Cooling Speed |
5.0℃/s(Max), 3.2℃/ s(Avg) |
||||
|
Temp. Accuracy |
±0.1℃ |
||||
|
Temp. Uniformity |
≤ ±0.25℃ |
||||
|
Number of Temp. Control Areas |
6
|
||||
|
Gradient Temp. Range |
1-32℃ |
||||
|
Hot-Lid Temp. Range |
104℃, Automatic Hot-lid |
||||
|
Special Function |
Absolute quantification, Relative Quantification, Genotyping, Amplification efficiency calculation, Melting curve. |
||||
|
Operation System |
Windows 7 64-bit or higher |
||||
|
Power Supply |
100~240V,50~60Hz |
||||
|
Dimension(L*W*H) mm |
600*390 *320 |
||||
|
Port Method |
USB Port |
||||
|
Packing Size(L*W*H) Mm |
850*600 *650 |
||||
|
Gross Weight |
51 |
||||